Mi-20-2KP fulfils ICAO Low Intensity Type A-B and DCA/M/A-B requirements:
Effective luminous Intensity: 20,000 cd white light (Day), 2,000cd Red Light (night)
ICAO Medium Intensity Type A
168 LED cluster (White LED) 20,000 cd
ICAO Medium Intensity Type B, 44
LED cluster, Red LED2,000 cd
(Red LED)
>3°
360° omni-directional
Factory Adjustable
AC 100 - 265V or DC 48
>40KA surge protection
-40°C to +60°C
IP67 (Lamp)
IP65 (Control Panel)
Resistant to shock and vibration
Photocell auto switching of lamp from White light(daytime) to red light (night time)
Ambient light
<50 Lux (±10%) = Red flashing
>50 Lux (±10%) = White flashing
White light 25 fpm (flash per minute)
Red light 25 fpm (flash per minute)
Flashrate selectable at factory
For remote monitoring of:
A. Power supply failure
B. Lamp failure
1. NO (Normally Open)
2. Com (Common)
3. NC (Normally Closed)
100mm
280mm
Lamp (2x 2kg)
Casing & misc (3kg)
Approx 7kg
Connect with us and let us help you. Find out more by contacting us via email or phone. We are ready to help!